JAKE JENSEN← All research
Abstract · ACSM 2027

Between-Day and Within-Session Reliability of Isometric Hamstring Force and Asymmetry in Three Positions

Jacob Jensen, Antonio Squillante, Jacob Goodin, Brent Alvar · Point Loma Nazarene University, San Diego, CA

Instrumented isometric devices are commonly used to test hamstring strength at 30° or 60° of knee flexion, or in prone position. Although knee angle alters isometric force output, these positions are often used interchangeably. The reliability of isometric force and rate of force development (RFD) across these positions is unclear.

Purpose

To determine the within-session and between-day reliability of isometric hamstring force, RFD, and asymmetry in three positions, and to identify the most repeatable position and most robust metrics.

Methods

Ten adults (age 23 ± 2 y; height 180 ± 10 cm; body mass 79 ± 9 kg) completed three sessions 48 to 96 hours apart after familiarization. Participants were tested on an instrumented isometric hamstring device at 30° (ISO30) and 60° (ISO60) knee flexion and prone at 0° (PRONE) in randomized order: efforts at 50% and 75%, then three maximal contractions (30 s rest). Bilateral and unilateral peak isometric force (BPIF, UPIF), time to peak force, RFD50, RFD100, RFD150, peak RFD, and asymmetry (|right − left| / stronger limb × 100) were averaged across trials. Reliability was assessed with Pearson r, ICC3,1 and ICC3,k (95% CI), CV, SEM, MDC95, and Bland-Altman analysis. Metrics were deemed robust when between-day ICC3,1 was ≥0.80 (lower 95% CI ≥0.50) in every position; the most repeatable position had the highest ICC3,1 and lowest SEM for BPIF.

Results

Only BPIF and UPIF met these criteria; time to peak, RFD, and asymmetry did not (ICC3,1 0.09 to 0.83). BPIF was consistent within sessions (ICC3,1 0.95 to 0.97; CV 4.6 to 7.9%; MDC95 14 to 23%) and reliable between days (ICC3,1: ISO30 0.86 [0.66, 0.96]; ISO60 0.85 [0.64, 0.96]; PRONE 0.88 [0.69, 0.97]; CV 12.2 to 16.7%; MDC95 33 to 45%). UPIF was similar (within session ICC3,1 0.94 to 0.96; between days 0.81 to 0.91, CV 10.1 to 20.6%). PRONE was most repeatable (lowest SEM). Mean BPIF was 589 ± 173 N in ISO60, 499 ± 209 N in ISO30, and 440 ± 153 N in PRONE.

Conclusion

BPIF and UPIF were reliable in all positions, with PRONE the most repeatable and ISO60 producing the highest force. Because the between-day MDC95 was about twice the within-session value, only changes beyond 33 to 45% can be attributed to true adaptation rather than measurement error. Early RFD, time to peak, and asymmetry were not reliable enough for individual monitoring, and positions should not be used interchangeably.